適用場所
  • 監控保全系統
  • 網路系統及伺服器材
  • 醫療及安全緊急逃生設備
  • 各種工廠設備及工業應用
  • 各種資料處理與電訊衛星系統
  • 其他不容許斷電之貴重設備及工作環境
標準製造容量 :
7.5/10/15/20/25/32/40/60/80/100/125 kVA

瀏覽更多內容
產品特色
  • This means that the JOVYSTAR delta is the optimal solution, as great reliability of the systems is our top priority. Our entire organisation and 55 years of experience in power supply technology stand for this.
  • The JOVYSTAR delta is a real on-line system (double conversion, permanent conversion),it therefore protects against all power faults and power failures.
  • The JOVYSTAR delta is available from 8,5kVA-125kVA. In units up to 32kVA, the batteries for short autonomy periods can be integrated in the UPS housing. The display and operating elements ao the JOVYSTAR delta have been designed ergonomically.
  • This means that the JOVYSTAR delta is the optimal solution, as great reliability of the systems is our top priority. Our entire organisation and 55 years of experience in power supply technology stand for this.
  • Output isolating transformer
  • Input-output insulation (operating from inverter)
  • Manual By-pass
  • Low harmonic distortion rejected into the mains
  • Automatic battery Test
  • IGBT technology for high frequency commutation
  • High crest factor
  • Capability of supplying distorted loads, containing output voltage distortion
  • up to 6 units in parallel redundant configuration
  • RS 232 - RS 485 serial interfaces
  • High instantaneous overload capability
  • High MTBF (>150.000h)
  • Low MTTR (<0,5h)
  • High efficiency starting at 25% load
  • Easy installation and maintenance; total accessibility from the front
  • Reduced dimensions
  • Easy to use and manage, with piloted start-up and friendly diagnostic
  • SNMP
  • Control software for WINDOWS®
  • These systems are manufactured in accordance with the strict quality guidelines as defined by DIN ISO 9001.
規格說明
Technical Data
Connecting voltage 3x400V/230V +/1%
Mains frequency 50Hz/60Hz+/-5%
Output voltage 400V/230V 3ph., adj. to 380V/220V 3ph.
Tolerance of output voltage static +/- 1%, dynamic if load
Output frequency alternation from 0 to 100% +/- 5%%
battery operation 50Hz/60Hz +/-,001Hz
mains operation synch. range is 2%
Power factor (output) 0,8ind.
Overload 125%-10min. 200%-100ms 2000%-20ms
Distortion  
Temperature range 0℃ ~+40℃
MTBF >100000h
Crest factor 3
Operating mode on-line continuous conversion
Computer interface optional
Dimensions UPS  (WxHxD) 10-15kVA: 620mmx1150mmx660mm
20-40kVA: 620mmx1300mmx840mm
60-125kVA: 815mmx1620mmx630mm
Dimensions battery  (WxHxD) 10-15kVA: 470mmx1150mmx800mm
20-40kVA: 620mmx1300mmx800mm
60-125kVA: 910mmx1600mmx800mm
Protection degree IP 20
Humidity class F acc. DIN 40040
Radio interference level EN 50091-2
Performance dependent data
Nom. output power 10kVA 15kVA 20kVA 25kVA 32kVA
Input power nom. 10,4kVA 15,9kVA 20,8kVA 25,6kVA 32,6kVA
Input power max. 12,5kVA 18,7kVA 24,9kVA 30,5kVA 39,5kVA
Current coms. nom. 15A 23A 30A 37A 47A
Current coms. max. 18A 27A 36A 44A 57A
Efficiency at 100% >90% >90% >92% >92% >92%
Inverter-input power 8,9kW 13,3kW 17,8kW 22,2 27,8kW
Noise level (EN 50091) <55dB(A) <55dB(A) <55dB(A) >55dB(A) <55dB(A)
Heat dissipation 0,89kW 1,33kW 1,78kW 1,74kW 2,22kW
Cabinets using batt. 10min 1 1 1 2 3
Weight incl. batt. for 10min. 420kg 546kg 761kg 877kg 710kg
Cabinets using batt. 30min. 1 3 2 3 3
Weight incl. batt. 30min. 444kg 662kg 861kg 881kg 1181kg
Weight UPS without battery 250kg 310kg 330kg 350kg 400kg
Performance dependent data
Nom. output power 40kVA 60kVA 80kVA 100kVA 125kVA
Input power nom. 40,9kVA 68,6kVA 91,5kVA 114,3kVA 142,7kVA
Input power max. 49,2kVA 75,5kVA 100,5kVA 126kVA 157,3kVA
Current coms. nom. 59A 99A 132A 165A 206A
Current coms. max. 71A 109A 145A 182A 227A
Efficiency at 100% >92% >92% >92% >92% >92%
Inverter-input power 34,8kW 52,2kW 69,6kW 87,1kW 108,7kW
Noise level (EN 50091) <55dB(A) <55dB(A) <55dB(A) <55dB(A) <55dB(A)
Heat dissipation 2,8kW 4,2kW 5,6kW 6,9kW 8,7kW
Cabinets using batt. 10min 2 2 2 2 3
Weight incl. batt. for 10min. 921kg 1493kg 1553kg 1772kg 2546kg
Cabinets using batt. 30min. 3 3 3 4 4
Weight incl. batt. 30min. 1273kg 2283kg 2436kg 3360kg 3430kg
Weight UPS without battery 390kg 610kg 670kg 710kg 780kg